“Mask this hole” can mean three different things on a sheet metal drawing: keep powder out of the bore, protect an existing thread, or leave a contact pad around the hole free of coating. A plug in the bore does not define the pad on the face. If the only requirement is that a bolt or connector fits after coating, say that instead. A useful drawing separates where coating is prohibited from what the finished part must do.
Consider a folded equipment panel with a connector opening, a threaded fixing and a designated earthing point. The three features sit on the same panel, but each needs a different drawing note and a different first-off check.
Map the masked areas on the correct face
Identify the inside and outside faces and give each critical feature a reference. Dimension a masking boundary from a hole centre or another locating feature, not from the edge of a shaded patch on a printout. Specify the shape, extent and permitted variation of that boundary. If a mask edge may show on a cosmetic face, identify where a witness line is acceptable.
“No powder coat” is not necessarily the same as “bare base metal”. If the pretreatment must remain, or a contact area needs a particular surface condition or separate protection, state that requirement explicitly. For a designated earthing contact, follow the equipment designer’s detail. A visible powder-free patch alone does not establish electrical performance.
Write a different note for a contact pad, a thread and a clearance hole
E1 — contact pad: “Keep the annular area E1 on inside face A free of powder coat. See Detail E for the pad boundary and required surface condition.” On the detail, locate the ring and dimension its extent. Specify the bore wall separately if it also has to remain uncoated.
T1 — existing thread: “Protect the threads identified as T1 during coating. Check thread usability after finishing using the agreed gauge.” If the screw head seats on a face that also needs protection, mark that seat separately.
C1 — finished opening: “Verify connector fit in C1 after coating using the approved mating connector, revision shown.” If the customer requires a finished opening dimension as well, include it with its tolerance. A successful trial fit does not waive a dimensional requirement.
A fixing hole that only needs to pass a bolt is a fourth, simpler case: specify the finished clearance or the agreed fit check. Do not turn it into a bare-metal requirement unless there is a functional reason. Protocase’s masking examples illustrate why a masked face around a cutout and the inside edge of that cutout are different requests. Confirm feasibility for the actual geometry before releasing the drawing.
Separate the cut profile from final fit after powder coating
Coating on opposing edges can reduce the usable width of a slot or opening. Coating on two mating flanges can also change how a cover seats. That does not mean every profile should be enlarged by a standard allowance. Identify the critical finished opening or mating condition and agree the route with the fabricator. If the DXF already includes an allowance, say so; otherwise the same compensation could be applied twice. The laser-cut hole quality guide covers problems with the cut hole itself.

For a folded assembly, show which flange locates the panel and whether the gap or overall dimension applies after finishing. Supply a formed view or STEP file if the flat profile does not show the interface. That gives the CNC bending team a clear reference for the mating face.
What should the first finished panel be checked against?
- Mask location and appearance: compare E1 on the specified face with the dimensioned detail. Check for powder where contact is specified and unwanted exposure beyond the permitted boundary. Compare the visible coated face with the agreed colour and texture reference.
- Threads and openings: check T1 with the specified thread gauge or agreed functional fastener, as required by the drawing. For C1, use the named connector or gauge and verify the installation orientation, seating and retention. Record the drawing and mating-part revisions.
- Assembled fit and function: fit the cover to its tray and check the designated gaps, seating surfaces and access. Where electrical bonding is an acceptance requirement, the responsible party should use the method and limits in the project specification. A mechanical fit check cannot replace that test.
For a repeat batch, retain the approved drawing revision and first-off result. A change to the mating connector, powder system or contact-pad layout is a reason to revisit the affected check rather than approving the new batch against an obsolete sample.
Request a quote for powder-coated sheet metal parts in Singapore
Send the cut profile, a dimensioned PDF showing both faces and the masking details, and a formed view where relevant. Include the material grade, sheet thickness, finish reference, required quantity, first-off date and Singapore delivery location. If a connector or mating cover defines acceptance, tell us whether a sample is available and who approves the fit. Confirm handover arrangements before bringing parts to Ubi Tech Park.
For a drawing-based project covering the cut blank and downstream finishing, see our sheet metal laser cutting services in Singapore or send the panel drawing and masking requirements for review. If the finish has not yet been selected, start with the comparison of powder coating, anodising and passivation.